Effect of lateral smoke extraction on transverse temperature distribution and smoke maximum temperature under ceiling in tunnel fires
Yuantao Zhu,Fei Tang,Zunxin Zhao,Qiang Wang
DOI: https://doi.org/10.1007/s10973-021-10814-2
IF: 4.755
2021-05-05
Journal of Thermal Analysis and Calorimetry
Abstract:This paper studied the effect of lateral smoke extraction on the transverse temperature distribution and maximum smoke temperature beneath the ceiling. The experiments were conducted in a reduced model tunnel (1:8). In the experimental study of optimal aspect ratio of the smoke extraction vent, a series of experimental conditions were considered. Keeping the same area of vents, four kind aspect ratios were set (<i>n</i> = 1, 2, 3, and 4). In experiment investigation of ceiling maximum smoke temperature, under the best vent aspect ratio <i>n</i> = 3, four fire heat release (50 kW, 60 kW, 70 kW, and 80 kW) rates were considered. The experimental results showed that the lateral smoke extraction system will affect the transverse temperature distribution, the transverse temperature distribution curve shows good stratification phenomenon, and the maximum temperature point will offset to the direction of the lateral extraction vent. The data of the maximum temperature under different test conditions were analyzed, and the influence factors of lateral smoke extraction were considered. Finally, the correlation of the maximum smoke temperature under the influence of lateral smoke extraction was proposed.
chemistry, physical, analytical,thermodynamics