Parameter Design for Symmetrical CLLC-Type DC Transformer Considering Cascaded System Stability and Power Efficiency

Xin Zhang,Fanfan Lin,Hao Ma,Bin Zhao,Jingjing Huang
DOI: https://doi.org/10.1007/978-981-19-9115-8_6
2023-01-01
Abstract:The symmetrical CLLC-type DC transformerDC transformer (DCT), with its high power density and exceptional capability for bidirectional power transfer, has been widely used in DC microgrids. It presents some difficulties for the parameter design of the CLLC-type DCT to meet the following two design requirements since the actual values of the inductors and capacitors in the circuit may change due to fluctuations in temperature and power. First of all, it is anticipated that the CLLC-type DCT will remain stable when it is cascaded with a constant power load (CPL), even though the output impedance is impacted by changing inductor and capacitor values. Second, even if the inductors or capacitors fluctuate, the CLLC-type DCTDC transformer is anticipated to retain an acceptable power efficiencyPower efficiency. This work proposes a four-stage PSOPSO-aided parameter design approach for the CLLC-type DCT that completely accounts for the unpredictable fluctuations of real-world inductors and capacitors to satisfy both design requirements, cascaded system stabilityCascaded system stability, and adequate power efficiency. With this proposed method, the CLLC-type DCT can operate steadily when it is cascaded with CPL and achieve the power efficiencyPower efficiency criterion even if the values of inductors or capacitors change. Finally, experimental evidence has been presented to support the efficacy of the proposed four-stage PSO-aided parameter design approach.
What problem does this paper attempt to address?