Analysis of the Influence of EXV on Heat Pump Air Conditioning System Based on AMESim

Tinglu Tian,Chao Wang
DOI: https://doi.org/10.24214/jecet.c.12.2.23041
2023-01-01
Journal of Environmental Science Computer Science and Engineering & Technology
Abstract:In order to analyze the law of the influence of EXV on the performance of the heat pump air-conditioning system, the R134a pure electric vehicle heat pump airconditioning heating system was taken as the research object, and the simulation model of the heating system was built based on the AMESim simulation platform.Comparative analysis of internal temperature rise, and analysis of the influence of EXV opening on compressor inhalation and discharge pressure, temperature, system heating capacity, and COP.The simulation results show that: compared with the traditional TXV air-conditioning system, the use of EXV can make the air-conditioning system achieve better operating results, and in low temperature environments, EXV has better adjustment capabilities; its opening is regulated by the PID control system, sensitive response, stable transient process.The research results provide a reference for the regulation of the performance of the pure electric vehicle heat pump air conditioning system and the formulation of control strategies.
What problem does this paper attempt to address?