Experimental Investigation of Vapor-Injection Co2 Heat Pump System Working Range from -30 °C to 50 °C for Electric Vehicles

Tianyang Yang,Huiming Zou,Mingsheng Tang,Changqing Tian,Yuying Yan
DOI: https://doi.org/10.2139/ssrn.4106276
2022-01-01
SSRN Electronic Journal
Abstract:In this study, a vapor-injection transcritical CO 2 heat pump system with flash tank for electric vehicles was built up, and the cooling and heating performance characteristics in a wide temperature range from -30 °C to 50 °C were experimentally studied. Compared with the basic system, the cooling capacity and coefficient of performance (COP) of vapor-injection system are increased by 16.8% and 9.5% with the opening of electronic expansion valve 2 (EEV2) at 62.5%, and the cooling performance is equivalent when the opening of EEV2 is 65%. The COP and heating capacity of vapor-injection system are increased by 11.7% and 41.8% at 0 °C, 45.5% and 75.7% at -30 °C. The refrigerant flow distribution characteristics under different working conditions and system regulation show that there is a highly linear positive correlation between the injection ratio and pressure ratio. Based on the experimental results and theoretical analysis of vapor-injection twin rotary compressor, a mathematical model was established, and the deviation between the predicted results and experimental data is within ±15%, but the slope of injection ratio in the heating mode is greater.
What problem does this paper attempt to address?