ASSESSING THE RELATIVE IMPORTANCE OF MUCOSAL EXPOSURE AND INHALATION EXPOSURE TO AIRBORNE PARTICLES

Mengjie Duan,Li Liu,Guillaume Da,Evelyne Géhin
DOI: https://doi.org/10.54337/aau541653952
2023-01-01
Abstract:Particles deposited on mucosa or penetrating into lower airway are two exposure routes. Quantifying administered dose of these two routes gives us idea for future advanced individual protection. Here, we report an in-vitro method to assess the administered doses of eyes, lips, and lower airway. A CT scanning and 3D-printing based human replica is developed, and exposed in front of the 0.6-5μm monodispersed fluorescent particles. At small size particles (<2.5 μm), the administered dose intensity of penetrating into lower airway inhalation (~59.41×10-2 g/g, 0.6μm) is higher than that of eyes and lips (~5.97×10-2 g/g, 0.6μm). Conversely, the administered dose intensity of lower airway inhalation (~9.39×10-2 g/g) becomes higher than that of eyes and lips (~6.24×10-2 ) g/g at 5.0μm particles. This work provides us an effective and economical way to assess exposure risks of particulate contaminants.
What problem does this paper attempt to address?