Experimental Study on Strong Wall-Weak Beam Reinforced Concrete Non-Planar Beam-Wall Connection

Jiaru Qian
2008-01-01
Abstract:To study earthquake resistant behavior of reinforced concrete(RC) non-planar beam-shear wall connection with built-in column in the shear wall,tests of 6 specimens were carried out under cyclic vertical loads applied at the cantilever beam end.All specimens were designed with strong wall(built-in column)-weak beam.The main parameters of the specimens included width of built-in column,reinforcement of built-in column and anchorage of beam longitudinal steel bars in the built-in column.Test results indicated that beam longitudinal bar yielding preceded the development of maximum load-carrying capacity.Tensile failure of wall concrete was occurred for the specimens that the anchorage of beam steel bars in the wall was not strengthened.The specimens with the width of built-in column being three times of the beam width and the anchorage of beam steel bars being strengthened had beam flexural failure corresponding to large deformation capacity.The specimens with the width of built-in column being four times of the beam width had the failure of both beam and wall.On the basis of the test results and the current standards the design recommendations of built-in column of non-planar beam-wall connection are presented,such as: the width of built-in column should not be larger than three times of the beam width,the out-of plane design moment of the built-in column should be determined according to the actual earthquake resistant moment capacity of the connecting beam,the minimum steel ratio of the built-in column should not be less than 1.0%,the minimum diameter of the stirrup is 10mm and the maximum space is 150mm,and so on.
What problem does this paper attempt to address?