Abstract:Aimed at difficult treatment of high algae raw water under high temperature,a pilot-scale study was made using ozone/biological activated carbon(BAC) process.The result indicates that organic matter can be removed effectively by ozone/BAC process.The removal rates of CODMn and UV254 are 73.76% and 86.38% respectively.Because of high temperature,a lot of breeding bacteria flow out of the reactor with the treated water.Low dosage of chlorine(1 mg/L) is effective to inactivate most breakthrough bacteria(lethality 99%).The bacteria in the treated water are under 10 CFU/mL,and safety of microorganism in the treated water is achieved.At the same time,a backwashing should be conducted at 3 to 4 day intervals in order to avoid the breeding bacteria clogging interspaces in activated carbon.The ozone/BAC process can remove 75% algae and no algae toxins are detected in its treated water.