Prevention of Tubular Copper Conductor in Water-Cooling Generator

Xie Xue-ju,Shunan Cao
2007-01-01
Abstract:On the basis of expounding the corrosion mechanism of the tubular copper conductor in the water-cooling generator, four methods of preventing corrosion of the tubular copper conductor in the water- cooling generator have been proposed. The corrosion of the tubular copper conductor could be prevented effectively and conveniently by keeping pH of the cooling water between 7. 5 and 8.0 by adding amine to the deionized water or giving partly the condensed water to the cooling water, and by adding low dosage and high efficiency copper inhibitor to the cooling water. The result of inhibitor application on the spot showed that the added dosage of the inhibitor developed by us was low, being lower than 5 mg/L, and that the efficiency of the inhibitor to copper was good, and the quality of the cooling water was stable. During the period that the inhibitor was added to the cooling water, the conductivity of the cooling water was lower than 2. 0 μS/cm, the content of copper in the cooling water is lower than 40 μg/L.the pH in the cooling water was higher than 6. 8.