Vacuum Brazing of Biomedical TNZ Alloy to ZrO 2 Ceramic Using Sn–Zr Filler: Interfacial Microstructure and Mechanical Properties

Bin Shi,Yunfei Cao,Xiukai Chen,Chen,Hong Bian,Xiaoguo Song,Qijuan Dong,Wei Fu,Yuzhen Lei
DOI: https://doi.org/10.1007/s10853-023-09068-0
IF: 4.5
2023-01-01
Journal of Materials Science
Abstract:The Sn–Zr filler metal is developed to braze Ti–13Nb–13Zr (TNZ) alloy and ZrO 2 ceramic for biomedical field. The impact of brazing processing parameters on the interfacial microstructure as well as mechanical properties is comprehensively examined and discussed. The typical interfacial microstructure of the joints is TNZ/Ti 6 Sn 5 /Ti 6 Sn 5 + ZrSn 2 + β -Sn/ m -ZrO 2 / t -ZrO 2 , which is obtained at 700 °C for 30 min. Zr active element contributes to the metallurgical bonding between brazing seam and ZrO 2 substrate. As the brazing temperature and holding time increase, there is a rise in the quantity of Ti 6 Sn 5 phase and m -ZrO 2 , while the content of ZrSn 2 phase declines. The brazed joints exhibit an optimum shear strength of 38.8 MPa when joints are brazed at 700 °C/30 min. The amount of ZrSn 2 phase and m -ZrO 2 has a powerful influence on mechanical properties of joints.
What problem does this paper attempt to address?