Analysis and Suppression of Common-mode EMI Using Synchronous Pulsed Compensation in Power Electronics
Siyong Luo,Chuang Bi,Wei Bao,Fan Li,Desheng Zhou
DOI: https://doi.org/10.1109/jestpe.2024.3443849
IF: 5.462
2024-01-01
IEEE Journal of Emerging and Selected Topics in Power Electronics
Abstract:A common-mode (CM) conducted electromagnetic interference (EMI) noise, exhibiting characteristics similar to a pulse signal, is produced during the rapid rise and fall of the drain-to-source voltage of the switching device. In order to eliminate the above CM conducted EMI, a reverse pulse signal, which is denoted by a synchronous pulsed compensation (SPC) signal, is proposed in this article. First, high-frequency equivalent circuits, based on a SiC half-bridge module, are built to determine the time-domain CM conducted EMI noise. Then, the impact of digital filter circuits with/without SPC signals on CM EMI noise is analyzed through the calculation of insertion loss. In addition, the design of the SPC signal is described in detail. To implement SPC, a digital active EMI filter (DAEF) system is constructed. Next, the overall experimental setup is elaborated upon. The measurements, performed on a 1000W buck DC-DC converter prototype, finally confirm the SPC method for CM conducted EMI suppression in the lower-to-medium frequency range.