Modified Brillouin Intensity Measurement Method for a General Brillouin Scattering System

Qian Guo,Peijin Shang,Shiyu Wang,Caizi Zhang,Fangfei Li
DOI: https://doi.org/10.1063/5.0152607
IF: 2.877
2023-01-01
Journal of Applied Physics
Abstract:A modified Brillouin intensity measurement method was developed in this study. A means of adjusting a modern Brillouin scattering system to apply the methods presented in previous literature was identified, an analysis model of the geometric factors for a given light path in a Brillouin scattering system was proposed, and ambiguous discussions in the literature due to the idealized modeling of geometric factors were addressed. The proposed model was expanded into a 60 degrees platelet symmetric geometry by measuring the elastic and elastooptical coefficients of MgO, KTaO3, and TeO2 samples. To avoid deviation, the geometric factor in experiments was considered, and various ways to circumvent it were identified.
What problem does this paper attempt to address?