Determination of Benzo [ A] Pyrene in Vegetable Oil by Solid Phase Extraction-Ultra Performance Liquid Chromatography-Fluorescence Detector
Feng Yinjie,Qiao Yongsheng,Chen Wei,Feng Chengyu,Ying Tiejin
DOI: https://doi.org/10.3785/j.issn.1008-9209.2015.05.011
2015-01-01
Abstract:Summary Benzo [a] pyrene (BaP) is a kind of polycyclic aromatic hydrocarbon , which is recognized as one of the three major carcinogens found in foods . The source of BaP detected in vegetable oil are as follows:BaP may occur when oilseeds are dried , smoked and stir‐fried; organic solvents used in the leaching process may have polycyclic aromatic hydrocarbons;oil heated over temperature or overtime in the process of production and cooking may produce BaP . The recommended national method for BaP determination in animal and vegetable fats and oils (GB/T 22509—2008) requires high experimental skills and long test time , making it difficult to guarantee the accuracy and repeatability of results . Besides , another standard on determination of BaP in foods ( GB/T 5009 .27—2003) is also complicated in sample pretreatment . In this study , a method for the determination of BaP in vegetable oil by solid phase extraction‐ultra performance liquid chromatography‐fluorescence detector ( SPE‐UPLC‐FLD) with a large volume flow cell was established . Oil samples were purified by four kinds of commercial solid phase extraction cartridges to compare extraction effects . Besides , the four types of chromatographic columns used in UPLC were tested to analyze separation effects . Samples were cleaned and enriched by commercial solid phase extraction cartridges . Then , the elution was dried by rotary evaporation and then was dissolved with acetonitrile‐tetrahydrofuran ( volume ratio , 9∶1) toaconstantvolume.SamplesolutionwasseparatedbyBEHShieldRP18column(50mm×2.1mm,1.7μm) with the mobile phase of acetonitrile‐water (volume ratio , 70∶30) at the flow rate of 0 .4 mL/min . Results showed that under the optimized conditions , a good linear relationship ( r>0 .999 993) was obtained in the range of 0 .101 10 .1 μg/L Bap , with detection limit of 0 .2 μg/kg . Recovery rates for four kinds of solid phase extraction cartridges were 91 .0% 106 .9% in three spike levels , and relative standard deviations ( RSD) were 1 .4% 9 .6% ( n=6) . Sample analysis by UPLC was three times faster than HPLC . In conclusion , this method has many advantages such as simple pretreatment , good repeatability , high sensitivity , less solvent and so on , thus can be applied on the rapid qualitative analysis and accurate quantitative detection of BaP in vegetable oil .