Abstract:Objective To explore the dense, over, and incomplete embolization of intracranial aneurysm. Methods One hundred and twenty cases (121 aneurysms) of intracranial aneurysm, which were embolized with MDS (mechanical detachable spiral) and/or GDC (guglielmi detachable coil) from March 1995 to July 1998, were analyzed retrospectivcely. Attention was paid especially to those which were embolized densely, over , and incompletely. Results Among 121 aneurysms, 100% occlusion was reached in 53 (43.8%, 53/121), 95% in 27 (22.3%), 90% in 16 (13.2%), 80% in 15 (12.4%), and less than 80% in 10 (8.3%) respectively. Over embolization occurred in 7 aneurysms in which 5 had wide neck (neck≥4mm or neck/transverse diameter≥2/3) aneurysms and the other two were situated in middle cerebral artery which was comparatively slender. Conclusion For intravascular embolization of intracranial aneurysm, one should try his best to obtain dense embolization, to avoid over embolization at any moment, and to handle incomplete embolization correctly