The Possibility and the Countermeasure of the Re-Rupture Within Procedure in the Embolization of Intracranial Aneurysms with Guglielmi Detachable Coils

李明华,顾斌贤,程英升,方淳,王武,徐涛,徐世定
DOI: https://doi.org/10.3760/j.issn:1005-1201.2004.06.008
2004-01-01
Abstract:Objective To study the possibility and the way to deal with the re-rupture within procedure for rupture aneurysms with Guglielmi detachable coil (GDC) embolization. Methods When 159 cases with intracranial aneurysms were treated with GDC embolization, the rupture during procedure occurred in 7 cases. Of them, the re-rupture was related to microguidewire in one cases, related to coils in 3 cases, related to microcatheter in 2 cases, and related to over-packing with coils in one case. Results A continuous packing with GDC with or without microcatheter adjustment, till a total occlusion of aneurysm, was performed in 3 cases with re-rupture related to coils and in 2 cases with re-rupture related to microcatheter. Of them, a complete recovery was acquired in 4 and a monoplegia remained in one case; Both the case with re-rupture related to microguidewire and the case with re-rupture related to over-packing with coils died due to intracerebral over-bleeding. Conclusion It is unavoidable that the re-rupture occurred during the procedure of GDC embolization of intracranial aneurysms. Its occurrence is in inverse proportion with operator's experience. The proper choice of coils may reduce the occurrence of re-rupture related to procedure. A continuous packing with coils is possible to get a total occlusion without any sequels in re-ruptured aneurysms.