Front-End Electronics of CXPD for Measuring Transient X-Ray Sources

Zongwang Fan,Hongbang Liu,Huanbo Feng,Yanjun Xie,Hui Wang,Ran Chen,Zuke Feng,Xiaochuang Xie,Enwei Liang
DOI: https://doi.org/10.1109/tns.2023.3269091
IF: 1.703
2023-01-01
IEEE Transactions on Nuclear Science
Abstract:The low-energy polarization detector (LPD), a payload of the POLAR-2 mission, is a soft X-ray polarization detector with a wide field of view and a large array aimed at measuring X-ray transients. These transients exhibit rapid intensity changes of several orders of magnitude, making it crucial for polarization detectors to have front-end electronics with low dead time, fast readout capabilities, high time resolution, and good energy resolution. In this article, we present the design of the front-end electronics, which consist of a rolling shutter CMOS pixel charge sensor (Topmetal- $II^{-}$ ) and a gas microchannel plate (GMCP) bottom amplifier circuit. Topmetal- $II^{-}$ ’s rolling shutter readout provides fast scanning of large pixel arrays without dead time and acquires 2-D images of photoelectron tracks. Meanwhile, the GMCP’s bottom amplifier circuit measures the energy and time of the X-ray. The front-end electronics are employed by the CubeSat cosmic X-ray polarization detector (CXPD), a proto-flight model of the LPD, achieving a timing resolution of 19 ns, and an energy resolution of 16.5% for linearly polarized X-rays at 8 keV.
What problem does this paper attempt to address?