A Transmissive X-Ray Polarimeter Design for Hard X-Ray Focusing Telescopes

Hong Li,Hua Feng,Jianfeng Ji,Zhi Deng,Li He,Ming Zeng,Tenglin Li,Yinong Liu,Peiyin Heng,Qiong Wu,Dong Han,Yongwei Dong,Fangjun Lu,Shuangnan Zhang
DOI: https://doi.org/10.1117/12.2185435
2015-01-01
Abstract:The X-ray Timing and Polarization (XTP) is a mission concept for a future space borne X-ray observatory and is currently selected for early phase study. We present a new design of X-ray polarimeter based on the time projection gas chamber. The polarimeter, placed above the focal plane, has an additional rear window that allows hard X-rays to penetrate (a transmission of nearly 80% at 6 keV) through it and reach the detector on the focal plane. Such a design is to compensate the low detection efficiency of gas detectors, at a low cost of sensitivity, and can maximize the science return of multilayer hard X-ray telescopes without the risk of moving focal plane instruments. The sensitivity in terms of minimum detectable polarization, based on current instrument configuration, is expected to be 3% for a 1mCrab source given an observing time of 10(5) s. We present preliminary test results, including photoelectron tracks and modulation curves, using a test chamber and polarized X-ray sources in the lab.
What problem does this paper attempt to address?