Effect of Geometry and Dimensions on the Upward Fire Spread in U-Shaped Structures

Yanqiu Chen,Xiankun Wang,Man Yuan,Peng Wang,Junmin Chen
DOI: https://doi.org/10.1007/s10694-021-01191-1
IF: 3.605
2022-01-21
Fire Technology
Abstract:U-shaped structures are very common in the facade of buildings, which have a significant impact on fire spread. In this paper, the effect of the geometrical factor (α), the cross-sectional area (A), the height (H) on the upward fire spread in u-shaped structures are analyzed based on the fire spread rate (Vf) and the pressure difference between the top and the bottom (ΔP) through full-scale experiments and simulations. A dimensionless structure parameter αH/Adocumentclass[12pt]{minimal}usepackage{amsmath}usepackage{wasysym}usepackage{amsfonts}usepackage{amssymb}usepackage{amsbsy}usepackage{mathrsfs}usepackage{upgreek}setlength{oddsidemargin}{-69pt}egin{document}$${{alpha H} mathord{left/ {vphantom {{alpha H} {sqrt A }}} ight. kern- ulldelimiterspace} {sqrt A }}$$end{document} is put forward to analyze the coupling effect of the structure size. It is found that Vf increases in the form of logarithmic function as α increases. ΔPmax increases in the form of exponential function as α increases; both Vf and ΔPmax decrease in the form of exponential function as A increases; Vf is positively correlated with H linearly. ΔPmax increases in the form of quadratic function as H increases; both Vf and ΔPmax increase in the form of Slogistic function as αH/Adocumentclass[12pt]{minimal}usepackage{amsmath}usepackage{wasysym}usepackage{amsfonts}usepackage{amssymb}usepackage{amsbsy}usepackage{mathrsfs}usepackage{upgreek}setlength{oddsidemargin}{-69pt}egin{document}$${{alpha H} mathord{left/ {vphantom {{alpha H} {sqrt A }}} ight. kern- ulldelimiterspace} {sqrt A }}$$end{document} increases. When αH/Adocumentclass[12pt]{minimal}usepackage{amsmath}usepackage{wasysym}usepackage{amsfonts}usepackage{amssymb}usepackage{amsbsy}usepackage{mathrsfs}usepackage{upgreek}setlength{oddsidemargin}{-69pt}egin{document}$${{alpha H} mathord{left/ {vphantom {{alpha H} {sqrt A }}} ight. kern- ulldelimiterspace} {sqrt A }}$$end{document} ≤ 17.2 or αH/Adocumentclass[12pt]{minimal}usepackage{amsmath}usepackage{wasysym}usepackage{amsfonts}usepackage{amssymb}usepackage{amsbsy}usepackage{mathrsfs}usepackage{upgreek}setlength{oddsidemargin}{-69pt}egin{document}$${{alpha H} mathord{left/ {vphantom {{alpha H} {sqrt A }}} ight. kern- ulldelimiterspace} {sqrt A }}$$end{document} ≥ 38.8, αH/Adocumentclass[12pt]{minimal}usepackage{amsmath}usepackage{wasysym}usepackage{amsfonts}usepackage{amssymb}usepackage{amsbsy}usepackage{mathrsfs}usepackage{upgreek}setlength{oddsidemargin}{-69pt}egin{document}$${{alpha H} mathord{left/ {vphantom {{alpha H} {sqrt A }}} ight. kern- ulldelimiterspace} {sqrt A }}$$end{document} has little effect on ΔPmax. The Vf in the non-overhead structure is very close to that in the overhead structure. This study can provide a theoretical guide for the fire protection design of u-shaped structures covered with insulation materials in practical engineering.Graphical abstract
materials science, multidisciplinary,engineering
What problem does this paper attempt to address?