Experimental Study on the Fire Spread in High-Rise Buildings with U-shaped Outside-Facade Structure

Jian-tao LI,Wei-gang YAN,Hong-ya ZHU,Qing-song WANG,Jin-hua SUN
DOI: https://doi.org/10.3969/j.issn.1004-5309.2012.04.01
2012-01-01
Fire Safety Science
Abstract:In this paper,the vertical fire spread experiments over small scale U-shaped structure with the typical organic thermal insulation material PU(polyurethane foam) were conducted.The vertical fire spread of the U-shaped structure and that of common structure were compared.The experimental results showed that the U-shaped structure vertical fire spread involves an acceleration process.The U-shaped structure of the high-rise building induces a chimney-like effect in the burning process which causes the acceleration of fire spread.The strength of the chimney-like effect increases when the structure factor is higher than 1.2.
What problem does this paper attempt to address?