Development and Verification of Containment Heat Sink Module in Severe Accident Code

Zhi Yang,Peng Zhou,Lin Chen,Yixuan Cheng,Hao Zhang,Yanhua Yang,Yichen Mao
DOI: https://doi.org/10.1115/icone29-91386
2022-01-01
Abstract:Abstract As an important part of COSINE software package, cosSA code is used for safety analysis of severe accidents in nuclear power plants. The containment heat sink can transfer the heat from the containment to the environment and thus decrease the risk of the containment failure, especially when the primary loop is broken. The containment heat sink module provides heat transfer calculation from gas space and water pool to the heat sink, so as to accurately predict the temperature of containment heat structure and gas temperature and pressure in the compartments. In this paper, the development of the containment heat sink module in cosSA code is introduced, including lumped parameter heat sink, distributed parameter heat sink, heat sink surface heat transfer, and inner heat conduction. In order to verify the current containment heat sink module, a series of tests are designed based on a simple case with three compartments. In general, the test results are in good agreement with the similar software for the totally submerged and totally uncovered heat sink, indicating the effectiveness and accuracy of the current containment heat sink module. For the partial submerged distributed parameter heat sink, the transfer to the gas space and water pool are calculated simultaneously. The axial division method can alleviate the extra heat transfer effect from gas space to water pool.
What problem does this paper attempt to address?