Simultaneous determination of 17 kinds of phthalate plasticizers in Baijiu based on GC-MS/MS

WU Aiying,SONG Chunyan,ZHANG Chenchen,XIANG Lixin,ZHANG Lin,ZHOU Yiran
DOI: https://doi.org/10.11882/j.issn.0254-5071.2023.04.039
2023-01-01
Abstract:A method for phthalates detection was established by gas chromatography-triple quadrupole tandem mass spectrometry(GC-MS/MS), and the contents of 17 phthalate plasticizers from different commercial Baijiu were detected. The results showed that, 17 phthalate plasticizers could be well separated under the condition of n-hexane as the extraction solvent, extraction temperature 40 ℃, and time 40 min. 17 phthalate plasticizers had a good linear relationship in the mass concentration range of 0-1 μg/ml, the correlation coefficient(R)≥0.996 5, the detection limit was 0.157-2.561 μg/kg,and the quantitative limit was 0.523-5.650 μg/kg. The average recovery rates of 17 plasticizers were 75.68%-98.56%, and the relative standard deviation(RSD) of precision test results were 0.125%-10.25%. The method had the characteristics of simple operation, high efficiency, low detection limit,good precision and accuracy rate, which was suitable for the rapid detection of 17 phthalate plasticizers in different Baijiu.
What problem does this paper attempt to address?