Determination Of Phthalate Plasticizers In Foods By High Performance Liquid Chromatography With Gel Permeation Chromatographic Clean-Up

Chunyu Zhang,Hui Wang,Xiaohui Zhang,Zhongqiang Ma,Wanmei Deng,Ke Hu,Mingyu Ding
DOI: https://doi.org/10.3724/SP.J.1123.2011.01236
2011-01-01
Chinese Journal of Chromatography
Abstract:A method of gel permeation chromatography-high performance liquid chromatography (GPC-HPLC) was established for the simultaneous determination of 5 main phthalate plasticizers in foods (edible oil, instant noodles, fried pastries, Saqima, etc.). The samples were extracted with petroleum ether in an ultrasonator, purified by a GPC column, and analyzed by HPLC. The chromatographic separation was achieved on a Labtech-C18 column (250 mm x 4.6 mm, 5 mu m) using acetonitrile and water mixture as the mobile phases in a gradient elution mode. The developed method exhibited a linear correlation coefficient of more than 0.997 and the detection limits of 3.25 - 13.4 mu g/L. The spike recoveries were between 70.4% and 113.6% with the relative standard deviations (RSDs, n = 3) of 0.3% - 5.8% at the spiked level of 50 mg/L. This method is simple, rapid and practical, and can be used for the simultaneous determination of PAEs in grease food samples.
What problem does this paper attempt to address?