Determination of 18 Phthalic Acid Esters in Drinking Water by Gas Chromatography-Tandem Mass Spectrometry with Solid Phase Extraction

Meng-meng ZHU,Min ZHOU,Lu-tao CHEN,Song HU,Lu-ping YU,Bin LI,Jin-feng HU,Chuan-pi WANG
DOI: https://doi.org/10.3969/j.issn.1005-6521.2018.12.026
2018-01-01
Abstract:A gas chromatography-tandem mass spectrometry(GC-MS/MS) was established for the determination of 18 kinds of phthalic acid esters (PAEs) in drinking water. The drinking water was enriched by hydrophilicl pophilibalance (HLB) glass column and eluted with dichloromethane, and then quantified by external standard method in multiple reactions monitoring mode (MRM). Under the optimized conditions, the target concentrations and peak areas were linearly correlated in the range of 0.02 mg/kg-1.00 mg/kg, and the correlation coefficients were greater than 0.998. Recovery studies were carried out on spiked matrices (the purified water) with 18 PAEs at spiking levels of 0.02, 0.1, 0.2 mg/kg and the mean recoveries were 71.3%-113 %, with relative standard deviations less than 6.8 %. Diisobutyl phthalate (DIBP), dibutyl phthalate (DBP) and bis(2-ethylhexyl) phthalate(DEHP) were detected in four chromatographic pure organic solvents:dichloromethane, methanol, n-hexane and acetonitrile which were concentrated 10 times. The content ranges were 0.00695 mg/kg-0.323 mg/kg. Multiple process blank tests could eliminate the interference of the reagents. The method has the advantages of high enrichment, fast and accurate, and can be used for the actual detection and analysis of 18 kinds of PAEs in drinking water.
What problem does this paper attempt to address?