Calculation of Penetration Depth under Various Numerical Models for the Reflection-Type Two-Coil Mutual Inductance Technique

Ningning Liu,Gang Yao,Yueqiao Qu,Xutao Wang,Jinyue Wang,Wenxuan Zhang,Mingchao Duan,Dan-Dan Guan,Shiyong Wang,Hao Zheng,Yao-Yi Li,Canhua Liu,Jin-Feng Jia
DOI: https://doi.org/10.1088/1361-6668/acb08d
2023-01-01
Abstract:The two-coil mutual inductance (TCMI) technique is a useful experimental method to derive the magnetic penetration depth lambda in a superconducting film after proper numerical calculations, in which various film geometries including infinite, circular and quadrangle films have been utilized. Based on previously reported reflection-type TCMI experimental data taken from NbN and K-adsorbed FeSe thin films, we investigate the validity of various numerical models with different geometries by comparing their calculation results. The calculated values of lambda for various film geometries become identical only when the film size is at least three times larger than the coil size. For a rectangular film with a width comparable to the coil size, the numerical models of circular and square film geometries with proper sizes can also be adopted to obtain a similar lambda value as that calculated with a rectangular film geometry. Although the true value of lambda can be approximately achieved only after a complicated calibration, its calculated temperature dependence is insensitive to the choice of numerical models. With these results, a proper film geometry for the numerical calculation of lambda may be selected to effectively improve the calculation efficiency.
What problem does this paper attempt to address?