Study on Mechanical Properties of (1 % PVA Fiber +1 % Steel Fiber) PS‐ECC under the Coupling Effects of Elevated Temperature and Dynamic Loads

Jianxing Chen,Zheming Zhu,Lei Zhou,Jinping Zhuang,Meng Wang,Leijun Ma
DOI: https://doi.org/10.1002/suco.202200070
2023-01-01
Structural Concrete
Abstract:The coupling effect of temperature and impact loads can cause the concrete strength to decay and lead to the failure of the structure that cannot reach the designed load-bearing strength. In this study, the evolution laws of dynamic compressive strength, dynamic increase factor (DIF), and absorbed energy of (1% polyvinyl alcohol [PVA] fiber +1% steel fiber) PS-ECC (engineered cementitious composite) were obtained by a split Hopkinson compression bar test. The conclusions can be concluded: the dynamic compressive strength, DIF, and absorbed energy of PS-ECC largely show a tendency to decrease with increasing temperature; however, the recovery effect occurs at 200 degrees C due to the accumulation of steam inside the specimen to counteract the impact force. Then, 200 degrees C becomes a threshold value, and the sensitivity of PS-ECC to strain rate shows a steep drop when the temperature exceeds 200 degrees C. Compared to 200 degrees C, the growth rate of dynamic compressive strength, DIF, and energy absorption capacity from strain rate 50-80 s-1 decreases by 50.65, 55.24, and 45.71% at 300 degrees C, the growth rate decreases by 55.87, 56.5, and 48.45% at 400 degrees C. The impact energy absorption of PS-ECC was provided mainly by PVA fiber. The energy absorption of PS-ECC is almost the same at 300 and 400 degrees C for the same strain rate due to PVA fiber burning disappears.
What problem does this paper attempt to address?