Baseline/acceleration/deceleration Determination of Fetal Heart Rate Signals Using a Novel Ensemble LCResU-Net.

Mujun Liu,Rongdan Zeng,Yahui Xiao,Jieyun Bai,Jia Liu,Zheng,Yaosheng Lu
DOI: https://doi.org/10.1016/j.eswa.2023.119610
IF: 8.5
2023-01-01
Expert Systems with Applications
Abstract:Objective: According to guidelines on electronic fetal heart rate (FHR) monitoring, visual FHR interpretation by obstetricians depends on the recognition of patterns (mainly including baseline, accelerations and decelerations (A/D)). Computer-assisted FHR analysis can effectively reduce obstetricians' inconsistency and improve fetal diagnosis efficiency. Precisely detecting patterns is one of the primary challenges of current computer-aided analysis. This study aims to propose an ensemble U-Net (augmented with residual, layer, and channel shortcut connections) (ELCResU-Net) with minimal post-processing to address the problem. Methods: In this study, A/D are firstly detected with the proposed ELCResU-Net in the FHR signal. After removing detected A/D, this signal is filtered using a progressive trimming procedure based on long-term and short-term frames that consider the continuity and stability of the baseline. Finally, the remaining signal is used to compute the baseline, and thereby A/D of FHR signals are determined. The proposed ELCResU-Net is composed of four LCResU-Nets with kernel sizes of 21, 31, 61 and 81, respectively. The LCResU-Net architecture consists of an encoder block and a corresponding decoder block followed by a point-wise classification layer to construct the 1D segmentation map of A/D from the input FHR signal. In the novel LCRes block of ELCResU-Net, three shortcut connections are used to dynamically prune unimportant channel/layer/block to improve the determination performance. Results: The proposed model is trained on the open-access training data set of the Catholic University of Lille France (CULF-DB) and then tested on its test data set and the independent database of the Jinan University (JNU-DB). Experimental results demonstrate that the proposed method achieves the accelerations' F1-score of 78.82 %, the decelerations' F1-score of 79.10 %, the baseline difference of 2.61 bpm, the synthetic inconsistency coeffi-cient of 49.99 % and the morphological analysis discordance index of 3.89 % in CULF-DB, which are the best performance ever achieved. On the JNU-DB dataset, the performance of the proposed method is also superior to most competing algorithms. Conclusion: The proposed ELCResU-Net for baseline/A/D determination of FHR signals achieves a high level of performance in morphological analysis.
What problem does this paper attempt to address?