Mechanism Analysis and Calculation Formula Improvement of Orifice Plate Pressure Drop Affected by Inner Angle

LI Haoran,LIU Lei,ZHANG Zeliang,BAI Changqing
DOI: https://doi.org/10.3969/j.issn.1005-0329.2022.11.008
2022-01-01
Abstract:For the problem that the existing formulas for the pressure drop of orifice plate cannot quantitatively express the influence of the inner angle of orifice plate, the CFD simulation model of orifice plate-pipeline system w as established for analyzing the pressure drop of orifice plate. By comparing the obtained results with the existing experimental data, the rationality of the simulation model was verified, and the significant influence of inner angle on pressure drop was validated. According to a large number of CFD numerical simulation results, the influence mechanism of inner angle on pressure drop was discussed. The internal law of interaction between inner angle, aperture ratio, thickness and pressure drop was described, and a new calculation formula for orifice plate pressure drop including inner angle effect was proposed. The comparison analysis shows that the improved formula is in good agreement with the CFD simulation and experiment results in the literature, and the errors are mostly below 5%. In the-45°~45°range, with the increase of the inner angle, the pressure drop decreases firstly and then increases, and finally tends to be constant. There is a minimum pressure drop.
What problem does this paper attempt to address?