Experimental and theoretical analysis of elemental mercury removal from syngas over Fe-Ti spinel

Xiaoyang Zhang,Lin Cui,Xiangwen Xing,Pengxiang Sun,Jiyun Tang,Juan Chen,Yong Dong
DOI: https://doi.org/10.1016/j.fuel.2022.124430
IF: 7.4
2022-01-01
Fuel
Abstract:A magnetic Fe-Ti spinel sorbent was synthesized by the co-precipitation method and applied to remove gaseous Hg0 from syngas. A superior Hg0 removal performance was achieved in the temperature range of 120–180 °C, and the highest an average removal efficiency of was approximately 95% at 150 °C under simulated syngas. H2S was adsorbed on the Fe-Ti spinel surface,which generated active sulfur species, and enhanced the Hg0 removal efficiency significantly. CO, H2 and H2O variably suppressed the Hg0 removal performance. H2S-pretreatment, X-ray photoelectron spectroscopy (XPS) and Hg0-temperature programmed desorption (Hg0-TPD) results demonstrated that Hg0 reacted with H2S over Fe-Ti spinel followed the Eley-Rideal mechanism, in which gas-phase Hg0 reacted with the active surface sulfur species generated from H2S oxidation and formed surface-bonded HgS. The surface Fe3+ and surface-active oxygen species were involved in the H2S and Hg0 adsorption and transformation process. Stability and regeneration cycling experiments indicated that Fe-Ti spinel exhibited excellent stability for Hg removal and great regeneration ability. Density functional theory (DFT) calculations showed that H2S underwent strong chemisorption on the Fe-Ti spinel surface with an adsorption energy of −116.988 kJ/mol, and then H2S further dissociated on the sorbent surface to generate active sulfur species, which reacted strongly with gas-phase Hg0 to form HgS.
What problem does this paper attempt to address?