Mach-Zehnder Interferometer Based Integrated-Photonic Acetone Sensor Approaching the Sub-Ppm Level Detection Limit.

Haoyun Niu,Peng Yu,Yisong Zhu,Zhimin Jing,Peihang Li,Baoqing Wang,Cuiping Ma,Jiaying Wang,Jiang Wu,Alexander O. Govorov,Arup Neogi,Zhiming M. Wang
DOI: https://doi.org/10.1364/oe.459805
IF: 3.8
2022-01-01
Optics Express
Abstract:The detection of acetone in the gaseous form in exhaled breath using an integrated sensor can provide an effective tool for disease diagnostics as acetone is a marker for monitoring human metabolism. An on-chip acetone gas sensor based on the principle of Mach-Zehnder interferometer is proposed and demonstrated. The sensing arm of the device is activated with a composite film of polyethyleneimine and amido-graphene oxide as the gas-sensitive adsorption layer. The composite film demonstrates good selectivity to acetone gas, can be used repeatedly, and is stable in long-term use. Room temperature operation has been demonstrated for the sensor with high sensitivity under a 20 ppm acetone environment. The detection limit can reach 0.76 ppm, making it feasible to be used for the clinical diagnosis of diabetes and the prognosis of heart failure.
What problem does this paper attempt to address?