Third-Harmonic Injection PWM Based Control Strategy for A Five-Phase Six-Leg Voltage Source Inverter With Unbalanced Loads

Shiqi Jiang,Panbao Wang,Wei Wang,Wei Wei,Dianguo Xu
DOI: https://doi.org/10.23919/ICEMS52562.2021.9634641
2021-01-01
Abstract:Compared to conventional n-phase topologies, the n-phase (n+1)-leg inverters are able to work under unbalanced loading conditions. This paper investigates the control strategy of a five-phase six-leg inverter system with unbalanced loads. Based on the third-harmonic injection pulse-width modulation (PWM) method, a double-closed loop control scheme with inner current loop and outer voltage loop is applied. Compared to an open five-phase five-leg inverter system, the designed system can balance the output multi-phase voltage with unbalanced loads, then realizing the required power distribution of different phases. Meanwhile, the generalized Park transformation is utilized in the controller to convert the referenced coordinate system to a rotating one from a natural coordinate system, which contributes to make the control system have a satisfied performance. Finally, the PLECS-based simulation verifies the designed strategy.
What problem does this paper attempt to address?