A Self-Reference Direct-Measuring Scheme for Precision Optical Frequency Ratio Measurement

Fang Pengcheng,Sun Huanyao,Wang Yan,Xu Yanqi,Chen Qunfeng
DOI: https://doi.org/10.1007/s00340-022-07794-y
2022-01-01
Abstract:A self-reference direct-measuring scheme for optical frequency ratio measurement is present in this work. The mathematical construction for the scheme is described in detail. An RF processing system was built according to the scheme. To examine the precision of the system, we measured the frequency ratio between the second harmonic and fundamental frequencies of a 1560-nm ultrastable laser. In 1 day’s measurement, a ratio of $$(2+1.2\times 10^{-22})\pm 1.4\times 10^{-21}$$ was obtained. The corresponding fractional frequency instability was $$5\times 10^{-19}$$ at the averaging time of 1 s and less than $$2\times 10^{-21}$$ at 1000–10,000 s. This result suggested that the precision of the RF processing system was sufficient for comparison of state-of-the-art optical clocks at the level of $$10^{-18}$$ .