Comparison of different impulse current measurement method during long air gap breakdown

Li ZhiZhao,Zeng Rong,Yu Zhanqing,Tian Feng,Chen She
2011-01-01
Abstract:Current is an important characteristic parameter to reveal the whole progression of long air gap discharge. It is difficult to measure the transient current at the high voltage side during breakdown because of high potential of instrument, large current amplitude, and the electromagnetic interference. In this paper, the advantages and disadvantages of instrument based on Rogowski coil, Current shunt, Electro-Optic Modulator were introduced and the properties of different methods were compared by experiment. Electromagnetic interference protection circuits for each instrument were applied during tests. Frequency spectrum characteristic of Partial Discharge, linearity and response time were measured and these characteristics can reveal the performance of different methods during measuring the breakdown current at the high voltage side. The waveform of current impulse that was measured at the high voltage side was performed and the effect of electromagnetic interference protection circuit was discussed. Current shunts and modulators can measure the DC component but coil can’t. Comparing to modulators, current shunts can acquire the current of pre-discharge and the current of breakdown in one discharge. Current shunt would be the most appropriate device for the observation of current in long air gap discharge.
What problem does this paper attempt to address?