Pre-breakdown Current Measurements from High Voltage Electrode of Rod-plane Gap under Lightning Impulse Voltage

GENG Yi-nan,ZENG Rong,HE Jin-liang,WANG Bo
DOI: https://doi.org/10.13336/j.1003-6520.hve.2011.04.013
2011-01-01
Abstract:A passive analog signal isolation transmission system based on the electro-optical integrated technology was proposed.This system with fibers as transmission medium was used to measure the streamer current from the high voltage electrode.The streamer currents of 1 m rod-plane gap energized by positive lightning impulse voltages were measured,of which the displacement current and discharge current were separated.The rinsing time of the current pulses produced by streamer was 80 ns,while the pulse width was 800 ns,and the injected charge increased as the applied voltage increased.
What problem does this paper attempt to address?