Analysis method on the break accident of the htr-pm refueling line

Lang Minggang,Li Zeguang,Xie Heng
DOI: https://doi.org/10.1299/jsmeicone.2019.27.1272
2019-01-01
The Proceedings of the International Conference on Nuclear Engineering (ICONE)
Abstract:In thermal hydraulics design and safety analysis of the HTRPM, the THERMIX code was used to study the behavior of the helium in the primary system. Once the helium leaks from the primary loop through a break or a relief valve, it is hard to simulate the states of the leakage room with THERMIX. In this paper, the latest version of RELAP5/MOD4 was used to simulate the behavior of the helium released to the containment rooms.
What problem does this paper attempt to address?