Research of SOFC Combined Heat and Power Systems with Natural Gas

Hao Meng,Minfang Han,Zaihong Sun
DOI: https://doi.org/10.1149/09101.0081ecst
2019-01-01
ECS Transactions
Abstract:In this study, three types of SOFC-CHP systems with natural gas were compared and analyzed, including basic type with external reforming, partial off-gas reflux type and reforming gas separation type. The effects of some parameters such as fuel flow rate, reformer temperature, stack temperature, and air inlet temperature on the energy efficiency of the system are analyzed. As results, increasing the fuel flow rate will reduce the electrical efficiency of the system. Increase of temperature in reformer and the stack temperature is always beneficial to the system electrical efficiency. Increasing the air inlet temperature will lead to lower electrical efficiency. For any fuel flow rate, there always exists an optimal operating current to maximize electrical efficiency. In addition, this study analyzed the operating costs of three types of systems, among which reforming gas separation type has the highest electrical efficiency and the lowest operating cost.
What problem does this paper attempt to address?