ICOPE-15-C027 Temperature Correction and Continuous Measurement for Escaping Ammonia in Power Plant Using 2.25μm Tunable Diode Lasers

Libin Yu,Fei Wang,Lifang Zhang,Jianhua Yan,Kefa Cen
DOI: https://doi.org/10.1299/jsmeicope.2015.12._icope-15-_127
2015-01-01
The Proceedings of the International Conference on Power Engineering (ICOPE)
Abstract:This paper selects absorption line near 2.25μm, and has temperature correction test range 20〜270℃, this allows more accurate measurement results. It makes relative error from 67.53% to 3.33% at 200℃. Design and install measuring gun, and realize continuous on-line measurement of SCR process ammonia slip of a power unit of Jiaxing Jies Power Plant, the measurement results basically reflect the real-time ammonia slip rate of this power unit. It lays the foundation for future power plant continuous on-line measurement technology for the escaping ammonia of SCR process.
What problem does this paper attempt to address?