MEASUREMENT OF CO CONCENTRATION USING TUNABLE LASER ABSORPTON SPECTROSCOPY TECHNOLOGY UNDER HIGH TEMPERATURE CONDITION

YAO Hua,WANG Fei,XU Ting,JIANG Zhishen,CHI Yong,YAN Jianhua,CEN Kefa
DOI: https://doi.org/10.3969/j.issn.1002-3364.2011.11.042
2011-01-01
Abstract:Based on the tunable diode laser absorption spectroscopic line(TDLASL) Techonology and the wavelength modulation spectroscopic(WMS) technology,and selecting the absorption spectroscopic line at 2302.12 μm,the measurement of CO concentration under 1000 K high temperature environment has been carried out,the result shows that the maximum error in direct measurement method is less than 5%,the maximum error in WMS method is less than 3%,the minimum detectable limit in unit optical length can reach 20×10-6.Through analysis of the two said methods,it is believed that the WMS method can effectively suppress the low frequency noise,enhancing the sensitivity of said system,making the measured value to be more close to the actual value.
What problem does this paper attempt to address?