The Heat Transfer Capacity of Multi-Layer Wick Heat Pipe Tested in Anti-Gravity Orientations

Xuewei Jiang,Hai Tang,Ying Liu,Lixian Lian
DOI: https://doi.org/10.1016/j.applthermaleng.2021.117611
IF: 6.4
2021-01-01
Applied Thermal Engineering
Abstract:To improve the heat transfer performance in the anti-gravity direction, the multi-layer wick heat pipe with three pore sizes was fabricated. The wick consisted of a coarse powder layer and a nanoporous fine copper powder layer. The critical heat load of the multi-layer wick was as high as 79 W in the 90 degrees direction, while the homogeneous wick sintered from coarse powder and nanoporous fine powder is only 23 W and 30 W, respectively. Multi-layer wick heat pipes with high heat transfer capacity will broaden their applications in terrestrial environments.
What problem does this paper attempt to address?