Fabrication and capillary performance of a novel composite wick for ultra-thin heat pipes

Huang Guangwen,Liu Wangyu,Luo Yuanqiang,Li Yong,Chen Hanyin
DOI: https://doi.org/10.1016/j.ijheatmasstransfer.2021.121467
IF: 5.2
2021-09-01
International Journal of Heat and Mass Transfer
Abstract:<p>The rapid development of high-performance portable electronics requires ultra-thin heat pipes (UTHPs) with higher heat transfer capacity to meet their heat dissipation needs. Wick structure, the key component of a heat pipe, makes a decisive role in the heat transfer capacity of the heat pipe. However, since the wall thickness of UTHPs is typically &lt; 0.1 mm, it is difficult to machine deep enough grooves on the shell to increase the permeability of the wicks like conventional heat pipes. Therefore, a novel composite wick structure with high permeability for UTHPs is proposed in this study. It is found that the wick with larger pores formed by parallel woven spiral meshes have higher permeability, resulting in more working fluid in the wick, which helps delay the drying out at the evaporation end of heat pipes. To further improve the capillary performance of wicks, the effect of thermal oxidation suitable for mass production on the capillary pumping performance of wicks is systematically studied for the first time. Compared with the single sintered wick, the capillary rise height after oxidation at 400 °C, 500 °C, 600 °C, and 700 °C for 150 min increased by about 32.2%, 19%, 19.5%, and 12.9%, respectively. Considering that the copper oxidation may limit the choice of working fluid for the heat pipe, the wicks are heated to 400 °C for reduction reaction for 1 h (with 95% N<sub>2</sub>+5% H<sub>2</sub> gas). The results show that the capillary rise height of the wicks after oxidation at 400 °C, 500 °C, 600 °C, and 700 °C and reduction treatment is about 110%, 127%, 114%, and 91.4% of that of the single sintered wick, respectively. The experimental results show that the maximum heat load power of the UTVCs with 5 layers #200 mesh, single sintered composite wick and 500 °C oxidation–reduction wick are 16 W, 29 W and 38 W, respectively.</p>
engineering, mechanical,thermodynamics,mechanics
What problem does this paper attempt to address?
The problem this paper attempts to address is: how to enhance the heat transfer capability of Ultra-Thin Heat Pipes (UTHPs) to meet the cooling demands of high-performance portable electronic devices. Specifically, the paper focuses on how to design and manufacture a novel composite wick structure to improve the permeability and capillary performance of ultra-thin heat pipes within very thin casings (typically less than 0.1 mm). ### Main Issues: 1. **Permeability Issue**: Due to the wall thickness of ultra-thin heat pipes usually being less than 0.1 mm, it is challenging to process sufficiently deep micro-grooves on the casing to increase the permeability of the wick material. 2. **Capillary Performance Issue**: Traditional wick structures cannot provide sufficient capillary force in ultra-thin heat pipes, limiting the heat transfer capability of the heat pipes. ### Solutions: 1. **Novel Composite Wick Structure**: The paper proposes a novel composite wick structure composed of three spiral woven meshes (SWMs) wrapped by two layers of flattened copper mesh. This structure provides additional fluid paths through larger pores, thereby improving permeability and capillary performance. 2. **Thermal Oxidation Treatment**: To further enhance capillary performance, the paper investigates the effects of thermal oxidation treatment at different temperatures on the capillary performance of the composite wick. The results show that after thermal oxidation treatment at 400°C, 500°C, 600°C, and 700°C, the capillary rise height of the composite wick increased by approximately 32.2%, 19%, 19.5%, and 12.9%, respectively. 3. **Reduction Treatment**: Considering that oxidized wick materials may limit the choice of working fluids, the paper also conducted reduction treatment. The results indicate that the capillary rise height of the composite wick after 400°C oxidation and reduction treatment was 110%, 127%, 114%, and 91.4% of that of the single-sintered composite wick, respectively. ### Experimental Verification: The paper experimentally verified the effectiveness of the novel composite wick structure and thermal treatment methods. The experimental results show that the maximum heat load power of ultra-thin heat pipes using 5 layers of #200 mesh, single-sintered composite wick, and 500°C oxidation-reduction treated composite wick were 16W, 29W, and 38W, respectively. ### Summary: By designing and manufacturing a novel composite wick structure, combined with thermal oxidation and reduction treatments, the paper significantly improves the heat transfer capability and capillary performance of ultra-thin heat pipes, thereby meeting the cooling demands of high-performance electronic devices.