Axial Velocity Distribution Of Particle Along The Radial Direction In Dilute Phase Of Riser

Hx Shi,Qh Wang,Zy Luo,Kf Cen
2005-01-01
Abstract:Particle Image Velocimetry (PIV) was used to investigate particle velocity field in a gas-solid circulating fluidized bed riser 4 in in height and 200mm X 200mm in cross-section. At certain axial position and different radial position in the dilute phase section, the axial velocity of particles along the radial direction was measured. The particle velocity vector fields were obtained by the Minimum Quadric Difference (MQD) cross-correlation algorithm suitable for high density of particles. At certain axial position and different radial cross-section, it was found that the magnitude of axial velocity near the central zone was higher than that near the wall of the riser. The results showed that the radial non-uniformity of particle flow structure, namely, the core-annulus flow along the whole radial cross-section existed. The effect of the superficial gas velocity, the height of bed materials and the original size of the particle on the axial velocity distribution of particles along the radial direction was also analyzed.
What problem does this paper attempt to address?