Thermodynamic Analysis of A Hybrid System Integrating an Alkaline Fuel Cell with an Irreversible Absorption Refrigerator

Mingzhou Zhao,Hongwei Zhao,Mengmeng Wu,Houcheng Zhang,Ziyang Hu,Ziqi Zhao
DOI: https://doi.org/10.1016/s1452-3981(23)11241-7
IF: 1.541
2015-01-01
International Journal of Electrochemical Science
Abstract:A hybrid system integrating an irreversible absorption refrigerator to an AFC (alkaline fuel cell) is proposed, where the AFC electrochemically converts the chemical energy contained in the inlet hydrogen into electricity and waste heat, the electricity is delivered to the external load and the waste heat is subsequently transferred to drive the absorption refrigerator for cooling purpose. By considering the main irreversible losses in the hybrid system, the operating current density interval of the AFC allows the absorption refrigerator to exert its function is determined and the numerical expressions for the equivalent power output and efficiency of the hybrid system under different operating conditions are specified. Numerical calculations show that the maximum power density and the corresponding efficiency of the hybrid system can be respectively increased by 2.6% and 3.0% compared to that of the stand-alone AFC. The general performance characteristics and optimum criteria for the hybrid system are revealed. Comprehensive parametric analyses are conducted to reveal the effects of internal irreversibility of the absorption refrigerator, operating current density, operating temperature and operating pressure of the AFC, and the heat loss from the AFC to the environment on the performance of the hybrid system.
What problem does this paper attempt to address?