The Development of High Performance Pulsed Magnets of the Prototype Facility of WHMFC
L. Li,T. Peng,H. Ding,X. Han,T. Ding,L. Qiu,Y. Lv,Y. Song,X. Duan,F. Herlach,Y. Pan
DOI: https://doi.org/10.1109/tasc.2010.2042585
IF: 1.9489
2010-01-01
IEEE Transactions on Applied Superconductivity
Abstract:Coils for pulsed magnets in the range of 50-75 T are developed with optimized combinations of conductors and reinforcement for the prototype laboratory of the Wuhan High Magnetic Field Center(WHMFC).The basic design tool is a Pulsed Magnet Design Software package(PMDS) for calculating the capacitor discharge,conductor heating,mechanical stresses and the residual stress,including plastic deformation and winding tension.A 1 MJ capacitor bank is equipped with a thyristor switch,a mechanical switch,polarity reversal switches,a current limiting inductor and a diode crowbar.The design and the test results of the magnets,of the protection inductance and of the capacitor bank are presented and discussed in this paper.