Passively Addressed FLC Display Possessing an Inherent Gray Scale and Memory
E. P. Pozhidaev,V. G. Chigrinov,Yu. P. Bobilev,V. M. Shoshin,A. A. Zhukov,A. L. Andreev,I. N. Kompanets,Li Xihua,E. E. Gukasjan,P. S. Komarov,O. A. Shadura,H. S. Kwok
DOI: https://doi.org/10.1889/1.2235695
2006-01-01
Journal of the Society for Information Display
Abstract:Abstract— A passively addressed 64 × 64 ferroelectric liquid‐crystal display (FLCD) has been developed. The display matrix has a 33 × 33 mm2 aperture, and the FLC layer thickness is 5.2 ± 0.2 μm. The display device operates with a frame frequency of 30 Hz (at Vrow = ±18 V, Vcol = ±9 V, T = 23°C), generating a continuous gray scale which can be memorized for more than 10 days after the driving voltage is switched off. A new approach for multiplex electronic addressing of the FLCD gray scale is proposed. The conditions of the hysteresis‐free gray‐scale generation for multiplex addressing and the gray‐scale memorization after the voltage is switched off, as well as the time steadiness of memorized images, are considered.