Research On The Strains Of Pumping Concrete At Minus Temperature

J. H. Li,J. P. Ou,J. H. Feng,Z. Wang
2006-01-01
Abstract:Strain sensors are embedded in concrete at negative temperature, by which the strain changes at different temperature (-5 degrees C and -15 degrees C) can be monitored. The results show that the strain sensors can be used to monitor the strain changes all through the curing process at different temperature; the time when maximum strain took place under different curing conditions could be detected. The strain almost keeps invariable in the curing process at negative temperature; the strain was approximately two times of that at the same curing time in negative concrete and reference concrete. The strains and its developing trend indicate the degree of damage of concrete. The temperature and curing time have an apparent influence on the change of strain in the period of freezing and thawing. During this period, the strains change tremendously in the first 4 hours, and then maintain steady.
What problem does this paper attempt to address?