Study On A Looped Thermoacoustic Prime Mover With A Compliance Tube

Rui Yang,Tao Jin,Yi Wang,Yuanliang Liu,Ye Feng,Ke Tang
2016-01-01
Abstract:Thermoacoustic heat engine is a type of machine converting thermal energy into acoustic energy with the attracting characteristics of high reliability and environmental friendliness. Recently, the thermoacoustic system driven by low-grade thermal energy (waste heat, geothermal energy and solar thermal energy, etc.) has been a hot research area. In this paper, a looped thermoacoustic engine with a compliance tube is proposed, where the compliance tube is utilized as the phase adjuster, to realize the high acoustic impedance and the near travelling-wave acoustic field in the regenerator, which is significant for effective thermoacoustic conversion. The onset temperatures for three different installation positions of the compliance tube have been investigated and the results show that the position which is 1/4 wavelength away from the cold heat exchanger is optimal. Systematic experiments have then been conducted with nitrogen, helium and carbon dioxide as working fluids. A lowest onset temperature difference of 37 degrees C (the corresponding heating temperature is 61 degrees C) was reached with the carbon dioxide as the working fluid with the mean pressure of 2 MPa. The exciting results show the promising usability of low-grade heat source in the thermoacoustic prime mover.