Simple Calculation Method Of Determining The Post-Fire Residual Strength Of Concrete-Filled Steel Tubular Columns

Kan Zhou,Lin-Hai Han
2019-01-01
Abstract:Existing studies on concrete-filled steel tubular (CFST) columns subjected to fire mainly concerns their performance at elevated temperature. Existing design approaches to determine the fire resistance of CSFT columns are available. However, actual fire has not only a heating phase, but also a cooling down phase. For structures using CFST columns that survive a fire without major structural failure, appropriate assessment and repair shall be conducted before these structures are back to service. Therefore, it is necessary to study the performance of CFST columns after exposure to fire. This paper first reviews existing research on the performance of CFST columns after fire exposure, concentrating on the calculation of post-fire residual strength. Then existing simple calculation method of determining the fire resistance in Eurocode 4 is extended for the calculation of post-fire resistance based on the concept of equivalent maximum temperature. The method is validated against available test data and is found to under-predict the measured failure loads by 20%.