Is the Equivalent Uniform Dose Model Being Used Properly? Impact of Dose Distribution on Parameter and Predictive Ability.

Q. Du,W. Liu,J. Li,H. Yue,H. Zhu,X. Li,Y. Gan,X. Ou,Q. Zhong,D. Luo,Q. Liang,Y. Xie,S. Zhu
DOI: https://doi.org/10.1016/j.ijrobp.2021.07.815
2021-01-01
Abstract:Volume-effect parameter of EUD is variable and depends on dose distribution rather than volume size. Before using an empirical parameter, dose distributions (especially the gradients) should be similar. Critical-dose-volume EUD could improve the predictive ability (no matter what the a is) and has a stable volume-effect parameter. Mean dose may be the case in which critical-dose-volume EUD has the best predictive ability, while median dose, as a simple dose/volume point, is a convenient alternative.