Effects of Inclined Condition on LOCA for a Small Offshore Reactor with OTSG

Zhiwei Cao,Jianchang Liu,Zhikang Lin,Jiang Yang,Xianghui Lu,Wenxi Tian
DOI: https://doi.org/10.1016/j.nucengdes.2021.111098
IF: 1.7
2021-01-01
Nuclear Engineering and Design
Abstract:A small offshore reactor called SMR-50 is conceptually designed for power supply in the ocean. The SMR-50 is a compact pressurized water reactor with two symmetrically arranged once-through-steam-generators (OTSGs). In this paper, the effect of inclined condition on the thermal-hydraulic behavior of the reactor during a postulated loss-of-coolant accident (LOCA) is analyzed. To simulate the transient under inclined condition, an analysis model is added into the thermal-hydraulic system analysis code RELAP/SCDAPSIM/MOD3.4. The simulation model of the reactor is developed and the LOCA transient under different inclined angles are simulated using the modified code. The results show that the inclined condition has a significant influence on thermal-hydraulic behavior of the reactor. Particularly, a rise of 500 degrees C in peak cladding temperate (PCT) is observed when inclined at a large angle in the plane of the two OTSGs. The inclined condition places a greater demand on safety systems of such a small offshore reactor and should be fully considered in the design process.
What problem does this paper attempt to address?