Comparative Analysis of Out-of-Band Power Handling Capacities for Lossy Filters

Liang-Feng Qiu,Lin-Sheng Wu,Bin Xia,Jun-Fa Mao
DOI: https://doi.org/10.23919/eumc48046.2021.9337972
2021-01-01
Abstract:A lossy filter can be applied as the receive filter in transceiver diplexers to achieve flat passband and sharp band-edges. The out-of-band power handling capacities of lossy filters are analyzed and compared with the derived formulas of power dissipation in resonators/resistors and the compact thermal models to predict temperature rise. For the prototypes of analysis, the nonuniform-Q filter loaded with resistors, the predistorted nonuniform-Q filter and the lossy coupled filter can be used when the power up to 57.1, 68.2 and 31.8 dBm is inputted into the transmit filter, respectively, when the maximum temperature rise is set to 50 K. The power handling capacity of lossy coupled filter is quite limited by the lumped resistors.
What problem does this paper attempt to address?