Moisture Location of Oil-Paper Insulated Bushing Based on Polarization and Depolarization Current Analysis

Guanwei Long,Haibao Mu,Daning Zhang,Yang Li,Guanjun Zhang
DOI: https://doi.org/10.1109/icd46958.2020.9342024
2020-01-01
Abstract:Bushing is the most important part of transformer to connect external component. Bushing fault is one of the prime reasons causing transformer faults. Moisture is an important factor leading to aging of bushing insulation, so it is necessary to evaluate the moisture content of bushing. In the current research, it can confirm whether the oil-paper insulation bushing is uniform damp. But there is no research related to the moisture location of oil-paper insulation bushing. We use Comsol software to carry out a simulation study of the finite element analysis method for nonuniform damp bushing. And the distribution characteristics of hydronium ions and hydroxide ions under electrode polarization can be obtained from the simulation analysis. In this paper, the polarization and depolarization current (PDC) experimental platform was set up and models of nonuniform damp bushings were made. The position information of the high-moisture capacitive screen can be obtained through two different wiring methods. The validity of the method can be verified by the distribution law of hydrolysis ions in this simulation.
What problem does this paper attempt to address?