Conversion factor analysis of self-balanced loading test of cast-in-situ piles based on analogue test method

Jianhang Li,Xiaojuan Li,Luchao Gao,Guoliang Dai,Weiguo Wu
DOI: https://doi.org/10.3969/j.issn.1003-7985.2019.02.007
2019-01-01
Abstract:Based on the characteristics of pile-soil interaction and the Mohr-Coulomb strength theory,a new method of determining the side friction at a pile-soil interaction is proposed.Combined with the actual engineering cases,the effectiveness of the analogue test method is verified by comparing it with the traditional anchor pile method and self-balanced method.Taking the self-balanced test of the bridge pile foundation in the Songhua River as an example,the conversion factor of sandy soil and weathered mudstone are confirmed by the analogue test method.The results show that the conversion factor of sandy soil and weathered mudstone in the Songhua River area should consider the geological conditions and the construction technology,etc.The standard values are relatively conservative.It is suggested that the engineering application should be properly revised.The recommended range of the conversion factor of sandy soil in this area is 0.65 to 0.85,and that of weathered mudstone is 1.0.
What problem does this paper attempt to address?